Directions 1
- Prior to operate the separator, ensure all the components are fastened, no broken on the sieves, no damage on the machine body, electrical cables are connected properly (do not use a knife switch), and three phase power supply is ready.
- Please check whether the machine model and specification are the same as your order. Power supply is the same as shown on the machine plaque. (Tolerance for voltage is + / – 10 %)
Preparation
- Place screen pots with required mesh onto the machine base sequentially.
- Feed raw material on the top screen pot, and then close the lid.
- Adjust the height of telescope poles accordingly and fasten the telescope knobs. Tighten the two black screen pot holding knobs to secure the lid.
Operation
- When power supply is on, the red power indicator comes on.
- Set the timer ( between 0 – 30 minutes ).
- Switch the start button, the green indicator comes on and machine starts working until the setting timing is up.
Directions 2
- Check the electrical components and all moving parts regularly during operation. Adjust if needed.
- This machine is guaranteed for one year under normal operating condition. Please contact our offices or distributors should any irregularity arise during the one-year warranty period. Do not under any circumstances attempt to make any repairs or replacements.
Configuration
- Screen pot holding knob.
- Telescope pole.
- Screen pot.
- Ventilation hole.
- Shock absorption rubber.
- Power.
- Telescope knob.
- Machine base.
- Timer.
- Power.
- Indicator.
Specification
Motor | Voltage | Frequency | Speeds (R.P.M) |
---|---|---|---|
0.3 HP | Single phaee: 110 V / 220 V Three phase: 220 V / 380 V / 415 V |
50Hz / 60Hz | 1440 / 1720 |
Maintenance
- Turn off power supply when the machine is not in use for an extended period of time.
- Clean the screen pots after operation, so they will be ready for use next time.
- Do not splash water on the machine to avoid current leakage.
- Turn the machine off immediately in the event of unusual noises and inspect for blockage or other irregularities.
- Always ensure the black knobs are securely tightened before operation.